云南中央空調效果好不好,絕大部分要看安裝工程好不好。除了品質可靠的產品,優質的空調安裝材料和安裝工程、專業靠譜的服務和售后同樣重要。以下是超詳細的中央空調安裝八大步驟!
01現場定位(wei) 室內機安(an)裝(zhuang)
進場第1步就是(shi)吊裝(zhuang)(zhuang)內(nei)機(ji),內(nei)機(ji)離(li)房(fang)頂距離(li)不(bu)(bu)得小于(yu)1公分,避免(mian)機(ji)器運行時與(yu)墻頂產生共(gong)振。室(shi)(shi)內(nei)機(ji)必須吊裝(zhuang)(zhuang)與(yu)水平(ping)(ping)位置(zhi),安(an)裝(zhuang)(zhuang)后需要用(yong)(yong)專用(yong)(yong)工具測量,機(ji)器是(shi)否水平(ping)(ping)。室(shi)(shi)內(nei)機(ji)用(yong)(yong)保(bao)鮮膜(mo)整齊的將整機(ji)做好(hao)防塵包(bao)裝(zhuang)(zhuang)保(bao)護(hu),防止灰塵堆(dui)積。室(shi)(shi)內(nei)機(ji)單獨固定,不(bu)(bu)與(yu)其他設備公用(yong)(yong)吊架(jia)(jia),且保(bao)證水平(ping)(ping)吊裝(zhuang)(zhuang)。配管(guan)與(yu)室(shi)(shi)內(nei)機(ji)連接處用(yong)(yong)保(bao)溫(wen)軟(ruan)管(guan)包(bao)好(hao),管(guan)道安(an)裝(zhuang)(zhuang)時不(bu)(bu)得與(yu)其它線管(guan)交叉,并在(zai)管(guan)道吊架(jia)(jia)上(shang)固定好(hao),管(guan)道固定橋架(jia)(jia)垂直于(yu)地面。
02冷媒(mei)管安裝
安裝完(wan)內(nei)機即可安裝冷媒銅(tong)(tong)(tong)管(guan),所有(you)的焊(han)接(jie)(jie)(jie)點應該(gai)是銅(tong)(tong)(tong)管(guan)與(yu)分歧管(guan)的連接(jie)(jie)(jie)處進行焊(han)接(jie)(jie)(jie),不存在(zai)銅(tong)(tong)(tong)管(guan)與(yu)銅(tong)(tong)(tong)管(guan)焊(han)接(jie)(jie)(jie)。在(zai)焊(han)接(jie)(jie)(jie)過程中必須在(zai)銅(tong)(tong)(tong)管(guan)內(nei)沖入(ru)氮(dan)氣(充氮(dan)焊(han)接(jie)(jie)(jie)工藝),使(shi)銅(tong)(tong)(tong)管(guan)內(nei)部沒有(you)空氣,避(bi)免(mian)產生焊(han)接(jie)(jie)(jie)使(shi)內(nei)壁結炭從而(er)在(zai)正式運轉(zhuan)時入(ru)壓縮機而(er)產生故障。焊(han)接(jie)(jie)(jie)完(wan)成后(hou)應該(gai)用(yong)高壓氮(dan)氣進行管(guan)內(nei)吹灰,保持銅(tong)(tong)(tong)管(guan)內(nei)清潔。

冷(leng)凝(ning)(ning)水(shui)管(guan)從(cong)內機(ji)接出(chu)后至室(shi)(shi)外(wai)或地漏(lou),至少(shao)保(bao)持>1%的(de)坡(po)度。質(zhi)量(liang)較高的(de)安裝(zhuang)則是從(cong)室(shi)(shi)內機(ji)接出(chu)后,就近落地,后面(mian)會同(tong)其他冷(leng)凝(ning)(ning)水(shui)管(guan)一起接出(chu)室(shi)(shi)外(wai)或地漏(lou)。
04打壓(ya)測試保壓(ya) 隱蔽(bi)工程驗收
充(chong)(chong)氮保(bao)壓(ya)(ya)(ya),焊(han)(han)接完成后必須對銅(tong)管(guan)進行壓(ya)(ya)(ya)力(li)測(ce)試(shi),往(wang)銅(tong)管(guan)內(nei)充(chong)(chong)入一(yi)定壓(ya)(ya)(ya)力(li)的氮氣(qi)(qi)進行保(bao)壓(ya)(ya)(ya),一(yi)般(ban)壓(ya)(ya)(ya)力(li)測(ce)試(shi)時間(jian)為(wei)24小(xiao)時。使用(yong)R410A冷(leng)(leng)(leng)媒(mei),需保(bao)持(chi)管(guan)內(nei)壓(ya)(ya)(ya)力(li)為(wei)40公(gong)斤(jin),R22冷(leng)(leng)(leng)媒(mei)則(ze)需要保(bao)持(chi)管(guan)內(nei)壓(ya)(ya)(ya)力(li)為(wei)20公(gong)斤(jin)。氮氣(qi)(qi)是惰(duo)性氣(qi)(qi)體,膨脹(zhang)系數小(xiao),幾乎不存(cun)在由于熱脹(zhang)冷(leng)(leng)(leng)縮而產生的壓(ya)(ya)(ya)力(li)變化(hua)。如(ru)果測(ce)試(shi)過(guo)程中壓(ya)(ya)(ya)力(li)表有(you)下降,則(ze)應該檢查冷(leng)(leng)(leng)媒(mei)管(guan)焊(han)(han)接是否(fou)有(you)問(wen)題。為(wei)了保(bao)證(zheng)安裝施工(gong)到(dao)(dao)位(wei),所有(you)壓(ya)(ya)(ya)力(li)表在常規24小(xiao)時保(bao)壓(ya)(ya)(ya)后不做拆除,為(wei)避免(mian)其(qi)他裝修施工(gong)時誤損(sun)冷(leng)(leng)(leng)媒(mei)系統(tong),保(bao)持(chi)到(dao)(dao)外(wai)機通電測(ce)試(shi)前才拆除,充(chong)(chong)分保(bao)證(zheng)冷(leng)(leng)(leng)媒(mei)系統(tong)的安全運行。
05風口安裝(zhuang)
通常回風(feng)口(kou)會(hui)與檢修(xiu)口(kou)安裝在一起,風(feng)口(kou)尺寸(cun)必須與內機回風(feng)口(kou)吻合,不(bu)能出現錯位(wei)情況,保證達(da)到較(jiao)佳回風(feng)量和足夠的維修(xiu)空間。
06控制器安裝 填充冷媒
在充填冷(leng)(leng)媒(mei)前需要(yao)對冷(leng)(leng)媒(mei)管(guan)進(jin)行抽(chou)真空(kong),把管(guan)內(nei)的空(kong)氣抽(chou)出,保持(chi)管(guan)內(nei)干燥、無水(shui)分,否(fou)則(ze)空(kong)氣和(he)水(shui)會與冷(leng)(leng)媒(mei)混合產生冰晶,嚴重的會造成設備損(sun)壞。冷(leng)(leng)媒(mei)管(guan)需要(yao)連(lian)接上外(wai)機后(hou)進(jin)行操作;抽(chou)真空(kong)的時間(jian)一般多聯(lian)機不少于兩小時,一拖一風管(guan)機不少于20分鐘。
07室(shi)外機安裝
室外(wai)機地面混凝土高(gao)度考慮到雪(xue)埋深度,高(gao)于地面150-200mm左右,同時留(liu)有排(pai)水(shui)溝以利于主機化(hua)霜水(shui)的排(pai)放(fang)。基礎表面平整,保證機器(qi)正(zheng)常運行,做到外(wai)機風(feng)扇出風(feng)口必須在(zai)50公分(fen)內外(wai)機后部15公分(fen)之內無遮擋物(wu),所(suo)有落地腳必須安(an)裝減(jian)震塊,保證外(wai)機運轉正(zheng)常。
08調試驗收
開啟冷(leng)媒(mei)閥,釋放出(chu)外機內自帶的冷(leng)媒(mei),開機測試并檢(jian)測壓(ya)力,適當進行補充,直(zhi)至調試完成。
對于文章內容你還有什么疑惑嗎?如果你還有很多不了解的問題或是未解決的問題,歡迎撥打澀澀免費網站:云南中央空調安裝公司的聯系電話與我們聯系。
相關文章
- 澀澀免費網站:云南中央空調公司告訴您空調室外機的9步清洗步驟2019年03月02日(ri)
- 澀澀免費網站:云南中央空調公司談多聯式中央空調的優點2018年12月(yue)28日(ri)
- 澀澀免費網站:云南中央空調公司介紹中央空調濾網清洗的方法2018年09月21日
- 澀澀免費網站:云南中央空調公司談中央空調耗能現狀2018年(nian)09月(yue)03日
- 澀澀免費網站:云南中央空調總代理講解為什么空調要抽真空?2018年08月08日